| Takagi Tankless Water Heater Quick Installation Check List |
| Category |
Sub-Category |
Description |
| Electrical |
Voltage |
120 VAC electrical ground all the way back to electrical service panel |
| Water |
Pressure |
A steady 50 - 60 PSI |
| Quality |
Hard water much be treaded with softener or conditioner |
| Well Water |
Water pressure must be checked & mineral contents treated |
| Pipe Material |
No galvanized supply water pipe |
Pressure Relief Valve |
Pressure relief only, no T&P |
Recirculation Line |
Recirculation lines should go through a small electric water heater and not directly back through the Takagi tankless water heater |
| Gas |
Gas Type |
Natural Gas or Liquid Propane - Option to specify is available when ordering |
| Pipe Size |
Minimum 3/4" I. D. (inside diameter) |
| Pressure (NG) |
7.0 WC (water column) ideally |
| Pressure (LP) |
10.0 WC (water column) ideally |
| Air |
Material |
Exhaust: 4" stainless steel, cat III Intake: 3" any material - seal connection |
| Layout |
4" exhaust must be individually run per unit all the way to outside
No common venting
No increase or decrease in diameter |
| Venting Length |
25 - 50ft depending on unit - Deduct 5ft for each elbow used in the venting |
| Condensation |
Must have condensation drain when linier run exceeds more than 5ft to protect heat exchanger |
Combustion Air Supply |
Air supply from outside: 1sq. Inch / 15,000 BTU Air supply from inside: 1sq. Inch / 1,000 BTU |